Our Facilities

ManagedWay has two Tier III+, SOC 2, Type 2, and HIPAA Audited, PCI Compliant Data Centers that are staffed 24/7/365. These state of the art Colocation facilities give your business peace of mind, availability of critical systems, and security from experienced professionals.

600 Executive Drive Troy, MI 48083 (TYM2)

Overview
  • 50,000 SQ FT
  • 100% uptime guarantee
  • High power and cooling density (up to 30kW per cabinet)
  • Network speeds up to 100Gbps+ available
  • Quarter cabinets, half cabinets, and full cabinets
  • Individually locked cabinets, cages, and private rooms/suites available
  • Carrier neutral facility
  • Over 30+ carriers available- just a cross connect away
Compliance
  • Tier III+ Facility
  • Policy Compliant – SOC 2 Type 2 Audited, HIPAA Audited, and PCI Compliant
  • 24/7/365 Remote Hands – Available with all Colocation services
  • 24/7/365 Building & data room access
Power
  • Diverse A & B Power Available – fully separate PDUs, Panels, Transformers, UPSs, and Generators
  • Two separate utility feeds from two different substations – 4MVA capacity, ability to increase to 8MVA
  • UPS and Generator back-up power
  • Back-up diesel generation with 72 hours of run time
Cooling
  • Redundant 1,500 ton capacity mechanical cooling plant
  • High power and cooling density (up to 30kW per cabinet)
  • Diverse Chillers, Cooling Towers, and AHUs
  • Under floor leak detection
  • Remote temperature and humidity monitoring
  • Flexible cooling on demand  
Smart Hands
  • Power cycling, equipment and card resetting
  • Hardware replacement coordination
  • KVM over IP
  • Securing cabling to connections and basic wire management
  • Equipment racking, stacking and inventory
  • Shipping and receiving coordination
  • Observing, describing, or reporting on indicators or display information on equipment or consoles
  • Basic observation and reporting on the environment
  • 1 Hr. SLA – typical response time 1-5 minutes
Security
  • 24/7/365 video surveillance of the entire facility – monitored on site and remotely
  • Two-factor security – mandatory security code & keycard doors.
  • High security (man traps, check points, cameras, and dual access security)
  • 24/7/365 On-site Staff
  • Gated and privacy screened facility
Unloading/Loading
  • Concrete filled, steel raised floor – 400 pound loading capacity per sq. ft.
  • Secure, climate controlled, truckwell and loading dock – added convenience and security for installation and delivery
Carrier Neutral

The following carriers are just a cross-connect away: 

  • ManagedWay 
  • Crown Castle    
  • Telia   
  • Cogent
  • Metro Wireless    
  • Comcast          
  • Wide Open West
  • Everstream         
  • Windstream      
  • ATT
  • Verizon               
  • XO Communications / Verizon
  • Rocket Fiber
  • US Signal       
  • Transtelco
  • ACD.net           
  • Telnet             
  • Clear Rate          
  • CenturyLink / Level 3   
  • Zayo
  • Hurricane Electric   
  • Detroit Internet Exchange  / 123.net   
  • Spectrum    
  • Metronet / Lightspeed
  • PFN      
  • Other regional carriers

319 Executive Drive Troy, MI 48083 (TYM1)

Overview
  • 20,000 SQ FT
  • 100% uptime guarantee
  • Network speeds up to 100Gbps+ available
  • Quarter cabinets, half cabinets, and full cabinets available
  • Cages and private rooms/suites available
  • Carrier neutral facility
  • Over 30+ carriers available- just a cross connect away
Compliance
  • Tier III+ Facility
  • Policy Compliant – SOC 2 Type 2 Audited, HIPAA Audited, and PCI Compliant
  • 24/7/365 Remote Hands – Available with all Colocation services
  • 24/7/365 Building & data room access
Power
  • Diverse A & B power available (fully separate PDUs, panels, transformers, and UPSs) 
  • Reliable power (2MVA capacity) 
  • UPS and generator back-up power 
  • Back-up diesel generation with 72 hours of run time
Cooling
  • 400 ton mechanical cooling plant
  • High power and cooling density (up to 10kW per cabinet)
Smart Hands
  • Power cycling, equipment and card resetting
  • Hardware replacement coordination
  • KVM over IP
  • Securing cabling to connections and basic wire management
  • Equipment Racking and stacking
  • Shipping and receiving coordination
  • Observing, describing, or reporting on indicators or display information on equipment or consoles
  • Basic observation and reporting on the environment
  • 1 Hr. SLA (typical response time 1-5 minutes)
Security
  • 24/7/365 video surveillance of the entire facility – monitored on site and remotely
  • Two-factor security – mandatory security code & keycard doors.
  • High security (man traps, check points, cameras, and dual access security)
  • 24/7/365 On-site Staff
  • Gated and privacy screened facility
Unloading/Loading
  • Secure, climate controlled, truckwell and loading dock (added convenience and security for installation and delivery)
Carrier Neutral

The following carriers are just a cross-connect away: 

  • ManagedWay 
  • Crown Castle    
  • Telia   
  • Cogent
  • Metro Wireless    
  • Comcast          
  • Wide Open West
  • Everstream         
  • Windstream      
  • ATT
  • Verizon               
  • XO Communications / Verizon
  • Rocket Fiber
  • US Signal       
  • Transtelco
  • ACD.net           
  • Telnet             
  • Clear Rate          
  • CenturyLink / Level 3   
  • Zayo
  • Hurricane Electric   
  • Detroit Internet Exchange  / 123.net   
  • Spectrum    
  • Metronet / Lightspeed
  • PFN      
  • Other regional carriers